ÇѱÛÁ¦¸ñ(Korean Title) ¹èÅ͸® º¸È£È¸·Î ¸ðµâ¿¡ ´ëÇÑ ÀüÀÚÆÄ ³»¼º ½ÇÇè
¿µ¹®Á¦¸ñ(English Title) Electromagnetic Susceptiblity Experiments for Battery Protection Circuit Module
ÀúÀÚ(Author) ¹Ú°æÁ¦   À¯Á¾°æ   ÀÌ´ëÇå   ¿©ÁØÈ£   Á¶¿µ±â   ±èÁ¾±Ô   Kyung-Je Park   Jong-Gyeong Yoo   Dae-Heon Lee   Junho Yeo   Young-Ki Cho   Jong-Kyu Kim  
¿ø¹®¼ö·Ïó(Citation) VOL 21 NO. 02 PP. 0057 ~ 0058 (2017. 10)
Çѱ۳»¿ë
(Korean Abstract)
º» ³í¹®¿¡¼­´Â ¸®Æ¬ÀÌ¿Â ¹èÅ͸®ÀÇ ¹èÅ͸® º¸È£È¸·Î ¸ðµâ¿¡ ´ëÇÑ ÀüÀÚÆÄ ³»¼º ½ÇÇè¿¡ ´ëÇÏ¿© ¿¬±¸ÇÏ¿´´Ù. ÀüÀÚÆÄ ³»¼ºÀº Àü¿ø¼±, ÀÔÃâ·Â¼±, ¾ÈÅ׳ª Æ÷Æ® µîÀ» ÅëÇØ À¯ÀԵǴ ÀüÀÚÆÄ¿¡ ´ëÇÑ Àüµµ¼º ³»¼º°ú °ø°£ÀûÀ¸·Î ¹æ»çµÇ´Â ÀüÀÚÆÄ¿¡ ´ëÇÑ º¹»ç¼º ³»¼ºÀ¸·Î ³ª´­ ¼ö ÀÖ´Ù. ½ÇÇè ½Ã·á·Î S»çÀÇ ¸®Æ¬ÀÌ¿Â ¹èÅ͸®¸¦ »ç¿ëÇÏ¿´°í, Àüµµ¼º ³»¼º ½ÇÇè¿¡¼­´Â Surge(IEC 61000-4-5), Ring wave(IEC 61000-4-12), Damped oscillatory wave(IEC 61000-4-18)¿¡ ´ëÇÏ¿© ½Ç½ÃÇÏ¿´´Ù. º¹»ç¼º ³»¼ºÀº IEC 61000-4-3¿¡ µû¶ó ½ÇÇèÇÏ¿´´Ù.
¿µ¹®³»¿ë
(English Abstract)
In this paper, we have studied electromagnetic susceptibility tests of the battery protection circuit module of a lithium ion battery. Electromagnetic susceptibility tests can be divided into conducted susceptibility for electromagnetic waves flowing through power lines, input / output lines, antenna ports, and radiated susceptibility for spatially radiated electromagnetic waves. A lithium ion battery of S company was used as an experimental sample, and conducted susceptibility tests were conducted on Surge (IEC 61000-4-5), Ring wave (IEC 61000-4-12), and Damped oscillatory wave(IEC 61000-4-18). Radiated susceptibility tests were performed according to IEC 61000-4-3.
Å°¿öµå(Keyword) lithium ion battery   protection circuit module   smartphone   electromagnetic susceptibility   conducted susceptibility   radiated susceptibility  